FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.16  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package navify.fhir.r5.rdc#1.0.0 (78 ms)

Package navify.fhir.r5.rdc
Type StructureDefinition
Id Id
FHIR Version R5
Source https://simplifier.net/resolve?scope=navify.fhir.r5.rdc@1.0.0&canonical=https://roche.com/fhir/iop/StructureDefinition/ext-CalibrationStatus
Url https://roche.com/fhir/iop/StructureDefinition/ext-CalibrationStatus
Status active
Name ExtCalibrationStatus
Title ext CalibrationStatus
Experimental False
Description This CalibrationStatus extension is used to capture the Calibration status of the CGM Device. The CGM value in the observation resource will be considered when extension CalibrationStatus = `calibrated` if the extension: CalibrationStatus = `uncalibrated` then it will be not considered as a valid entry.
Copyright Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.
Type Extension
Kind complex-type

Resources that use this resource

StructureDefinition
https://roche.com/fhir/iop/StructureDefinition/rdc-Observation-CGM RDC Obseration CGM

Resources that this resource uses

No resources found



Source

{
  "resourceType" : "StructureDefinition",
  "id" : "ext-CalibrationStatus",
  "url" : "https://roche.com/fhir/iop/StructureDefinition/ext-CalibrationStatus",
  "name" : "ExtCalibrationStatus",
  "title" : "ext CalibrationStatus",
  "status" : "active",
  "publisher" : "F. Hoffmann-La Roche AG",
  "description" : "This CalibrationStatus extension is used to capture the Calibration status of the CGM Device.\r\n\r\nThe CGM value in the observation resource will be considered when extension CalibrationStatus = `calibrated` if the extension: CalibrationStatus = `uncalibrated` then it will be not considered as a valid entry.",
  "copyright" : "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.",
  "fhirVersion" : "5.0.0",
  "kind" : "complex-type",
  "abstract" : false,
  "context" : [
    {
      "type" : "element",
      "expression" : "Observation"
    }
  ],
  "type" : "Extension",
  "baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Extension",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "Extension",
        "path" : "Extension",
        "max" : "1"
      },
      {
        "id" : "Extension.url",
        "path" : "Extension.url",
        "fixedUri" : "https://roche.com/fhir/iop/StructureDefinition/ext-CalibrationStatus"
      },
      {
        "id" : "Extension.value[x]",
        "path" : "Extension.value[x]",
        "type" : [
          {
            "code" : "string"
          }
        ]
      }
    ]
  },
  "text" : {
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.